We clean reusable instruments, then sterilise them in a B-class autoclave, which uses steam under pressure with vacuum cycles so steam reaches inside hollow and wrapped instruments. Single-use items are used once and thrown away. Each appointment is planned with time for a full sterilisation cycle between patients, which is part of why we see fewer patients a day.
Sterilisation is invisible to most patients, which is exactly why it is worth asking about. Here is what happens to an instrument between your appointment and the next person's.
Items that cannot be reliably sterilised, or are designed for one use, are used once and discarded. These include needles, local anaesthetic cartridges, gloves, masks, suction tips and similar disposables. We use single-use items where single-use belongs.
Reusable instruments, such as mirrors, probes, forceps, scalers and handpieces, are cleaned first. Sterilisation does not work properly through dried blood or debris, so cleaning is not optional. It is a separate step done before anything goes into the steriliser.
Cleaned instruments are packed in sterilisation pouches or wraps so they stay sterile after the cycle until they are opened in front of you.
An autoclave sterilises with steam under pressure at high temperature. Autoclaves come in classes. A B-class autoclave, which is what we use, removes air with vacuum cycles before the steam phase. That matters because dental instruments include hollow parts, such as drill handpieces, and wrapped packs. Without removing the air, steam may not reach every surface. Simpler "N-class" units are designed for solid, unwrapped instruments only.
Our appointments are planned as about 80 minutes, and that includes a full sterilisation cycle between patients. A clinic that books someone every 15 minutes often has to rely on large instrument stocks or shortcuts. Our model is slower, and fees reflect it, but sterilisation is never the step that gets rushed.
Our sterilisation page, written during the COVID period, describes further measures we introduced then: hand sanitising at reception, personal protective equipment for the team, extra-oral suction to capture aerosols at the source during procedures, and fogging of the treatment room after procedures. Read it on our sterilisation page.
It helps to know what to be wary of anywhere. Boiling water, chemical dips used on their own, and the small UV cabinets sometimes seen on clinic counters do not reliably sterilise dental instruments. They can reduce germs, but they do not kill the hardy spores that a proper steam cycle does. UV cabinets are fine for storage at best. Steam under pressure in an autoclave is the standard that matters for anything that goes into your mouth and touches blood or tissue.
If you want to see the sterilisation area or ask how a particular instrument is handled, ask us. A clinic should be comfortable answering. For our full approach to infection control, see the About AR 32 questions.
Kharadi runs late. Reception will tell you honestly whether you need an appointment yet.